KH190 Portable Hardness Tester
Kairda portable hardness testers is using leeb method proves to be nondestructive testing, portable, achieving high testing rates at a reduced cost, mostly to inspect large hard metal parts, suitable for flat and round surface.
This portable hardness tester KH190 is 320*240 color display, high quality, including 7 scales HL, HS, HB, HR, HRB, HRA, HV, the HL scale and the prescribed scale you selected are shown same time (Showing dual scale according to impact Device and material).
This portable hardness tester KH190 features auto-probe detection, compatible with 7 type of impact device to solve various kinds of hardness testing applications.
The portable hardness tester KH190 supports hot swap. Provide PC software to export data through USB, convenient for data management. Support user defined material, automatic sound alarm, accuracy: ±6HLD , repeatability: ±6HLD
KH190, KH220 plus, KH530, these 3 models of portable hardness tester share the above high light features: 320*240 color display, showing dual scale, hot swap, user defined material.
The other mentioned features are the common features that all of our current LEEB hardness tester have.
Commodity Property
Type of Battery: 3 of AA battery
Battery Capacity: 4.5 v
Continuous working period: 60 H (if back light off)
Technical Data
Measuring Range
| HLD (170~960), for other scales see table TESTING RANGE
|
Indication Error
| ±6HLD (D impact device)
|
Measuring Direction
| 360°
|
Hardness Scale
| HL, HB, HRB, HRC, HRA, HV, HS
|
Data Memory
| Max 600 groups
|
Working Temperature
| -20°C~55°C
|
Size of main unit
| 79x34x45.5mm
|
Weight of main unit
| 0.226kg
|
Case Material | Plastic |
Measuring Range
KH190 leeb hardness tester measuring range is 170 to 960HLD.
Other scales: HRC (17.9-69.5), HB (19-683), HV (80-1042), HS (30.6-102.6), HRA (59.1-88), HRB (13.5-101.7)
The other scales depend on the material and the probe.
STANDARD PACKAGES
- Main Unit 1 PC
- D Type Impact Device 1 PC
- Standard Block 1 PC
- Small Support Ring 1 PC
- Nylon Brush (A) 1 PC
- USB Cable 1 PC
- Screwdriver 1 PC
- Data View Software 1 PC
- User’ Manual 1 PC
- Instrument Case 1 PC
Impact device scope of application
D Type Impact Device
Portable hardness tester with D Type Impact Device is used for solving of main hardness testing assignment.
D probe is around 147mm.D Type Impact Device is suit for sample of average roughness RA 1.6μm;
Minimum weight of samples required: the hardness tester with D type can directly test the hardness when the sample weight is 5kg or more,
if for 2kg to 5kg, the probe needs solid support, if the weight is 0.05 to 2kg, the sample need coupled on heavy item.
Minimum thickness: if for 5mm sample, the sample need proper coupled with heavy work piece, if for hardened layers, the layer thickness should be 0.8mm or more.
DC Type Impact Device
Portable hardness tester with DC Type Impact Device is used for confined spaces such as holes, internal measurements of cylinders.
DC probe is short:86 mm. the minimum weight of sample, and the minimum thickness are required same with D type impact device.
DL Type Impact Device
Portable hardness tester with DL Type Impact Device is used for confined space such as elongated narrow slot or hole.
DL probe is around 205mm, the measuring conditions is same with D type impact device.
C Type Impact Device
C Type Impact Device for portabe hardness tester is reduced impact energy, for testing hardened or thin-walled components, with average roughness RA required 0.4μm; C probe length is 141mm.
when the hardness tester with C type impact device, the minimum weight of samples required:
Direct testing: 1.5kg; On solid support: 0.5-1.5kg; Coupled on heavy item: 0.02-2kg
the minimum thickness of sample: 1mm, minimum thickness of hardened layer:0.2mm
D+15 Type Impact Device
D+15 Type Impact Device for hardness tester is for measurements in grooves, recessed surface, with average roughness RA required 1.6μm; D+15 probe length 162mm.
hardness tester with D+15 type impact device testing required the minimum weight of samples: Direct testing: 5kg, on solid support: 2 to 5kg, coupled on heavy item: 0.05 to 2kg.
The minimum thickness of sample: 5mm, minimum thickness of hardened layer:0.8mm
E Type Impact Device
E Type Impact Device for hardness tester is with diamond test tip for high hardness materials, with average roughness RA required 1.6μm, it measures max hardness 1200HV; the E probe is around 155mm.
portable hardness tester with E type impact device required:
Direct testing: 5kg, on solid support: 2 to 5kg, coupled on heavy item: 0.05 to 2kg. The minimum thickness of sample: 5mm, minimum thickness of hardened layer:0.8mm
Minimum weight of samples required: the hardness tester with D type can directly test the hardness when the sample weight is 5kg or more,